Industrial Power, Control & Instrumentation Cables

Specify industrial cables by voltage grade, conductor construction, core or pair geometry, screening, fire test evidence and delivery drum schedule. Grenglo coordinates broader electrical projects while specialist cable selection is supported through SGCables.

Product sourcing

Cable construction, fire performance and compliance matter.

Dedicated cable enquiries are also handled through our specialist channel, SGCables.com. Mixed project BOQs can come straight to Grenglo.

Typical requirements

  • LV power conductor size and insulation selection
  • Control cables, twisted instrumentation pairs and screening
  • LSZH, flame propagation and fire circuit integrity distinctions
  • PV DC cable requirements and accurate cut/drum schedules

Include in your RFQ

  • Uo/U or DC voltage, conductor size, Cu/Al and classes
  • Core/pair count, screens, armour, insulation and sheath
  • Fire, smoke and circuit-integrity tests where applicable
  • Project BOQ, cable lengths, cut/drums, delivery country
Product families

Five specified industrial cable families

Compare power, control, instrumentation, tested fire-behaviour and photovoltaic DC cables by construction and application. For Singapore buyers, manufacturer test reports and cable schedules are more useful than a generic coil picture.

LV power cables (0.6/1 kV and specified grades)E-03.1

LV power cables (0.6/1 kV and specified grades)

Extruded-insulation power cables used in fixed distribution circuits, with the actual voltage, conductor size, construction and installation method controlling selection.

  • Nominal conductor area and class
  • Core count, screen or armour
  • Insulation, sheath and fire properties
  • Voltage designation and tests
  • Drum lengths, packing and delivery
ApplicationsCommercial and industrial LV feeders, MCC supplies, fixed plant power distribution.
StandardsIEC 60502-1 (as applicable)
Put in your RFQ0.6/1 kV or other Uo/U; 1C/3C/4C; mm²; Cu/Al; XLPE/PVC; SWA/AWA if required; IEC test basis; individual drum lengths.
Selection guide

Specify Uo/U(Um), IEC or project standard, Cu or Al, conductor area and class, number of cores, XLPE/PVC/LSZH materials, armouring, sheath, operating temperature, installation conditions and drum lengths.

Ask about this →
Industrial multicore control cablesE-03.2

Industrial multicore control cables

Multicore control wiring requiring conductor identification and a defined balance between flexibility, shielding and insulation.

  • Number of cores and cross-section
  • Conductor class and core ID
  • Foil/braid screen and drain
  • Chemical/UV exposure and CPR if applicable
  • Length and drum takeoff
ApplicationsPLC control wiring, motor and auxiliary controls, equipment interlocks and panel-to-field connections.
StandardsIEC 60228 conductor classes; specified fire and installation tests
Put in your RFQCores × mm²; control voltage; numbered cores; stranded class; screen/drain; installation route; operating temperature.
Selection guide

Specify numbered or colour-coded cores; flexible/stranded class; mm², voltage, screen/overall foil or braid, oil/UV exposure, bend radius and required flame tests. Choose shielding to suit the control design rather than automatically.

Ask about this →
Shielded instrumentation pair/triad cablesE-03.3

Shielded instrumentation pair/triad cables

Cable constructions for low-level analogue or digital instrumentation signals; pair twisting and screening affect interference immunity.

  • Pairs or triads and conductor size
  • Individual/overall shields and drain
  • Capacitance and EMC design
  • Blue identification for intrinsically safe systems where specified
  • Installation and hazardous-area requirements
ApplicationsProcess sensors, 4–20 mA loops, instrument transmitters and process-control systems.
StandardsProject instrument cable specification and relevant IEC conductor/fire tests
Put in your RFQPair/triad count; conductor; individual/overall shielding; capacitance if required; armouring; sheath; standards.
Selection guide

Identify number of twisted pairs/triads, conductor area/AWG, individual and overall screening, drain wire, capacitance, characteristic impedance if relevant, armour, circuit segregation and intrinsic-safety colour/marking requirements where applicable.

Ask about this →
Fire-resistant, flame-retardant & LSZH cablesE-03.4

Fire-resistant, flame-retardant & LSZH cables

Fire propagation, smoke emission, halogen acid-gas emissions and circuit integrity are different performance requirements; no single marketing descriptor proves all of them.

  • Flame propagation test
  • Smoke/acid gas performance
  • Circuit integrity test and duration
  • Specified fire system and installation method
  • Authority/consultant acceptance
ApplicationsFire-alarm and emergency circuits, protected industrial installations, enclosed public areas when applicable.
StandardsIEC 60332-1-2; IEC 61034; IEC 60754; IEC 60331 as applicable
Put in your RFQExact fire tests and durations; Uo/U; conductor/core size; fire-resistance evidence; project-approved construction.
Selection guide

Obtain the exact test method: flame propagation (IEC 60332), smoke (IEC 61034), acidity/halogen (IEC 60754) and circuit integrity (appropriate IEC 60331 test) where the fire strategy requires them. Include full system and installation conditions.

Ask about this →
Solar PV DC cables (IEC 62930 type)E-03.5

Solar PV DC cables (IEC 62930 type)

Single-core DC cables designed for photovoltaic array use; specify rated system voltage, insulation, conductor and environmental exposure.

  • Rated DC voltage and temperature
  • Conductor size and cable outside diameter
  • UV/ozone/environmental resistance
  • Cable routing, termination and bend radius
  • IEC 62930 evidence and drum lengths
ApplicationsPV string-to-combiner and array DC interconnections.
StandardsIEC 62930:2017 — photovoltaic DC cables
Put in your RFQDC voltage, 1C × mm², cable OD, colour, IEC/EN compliance evidence, cut or drum lengths.
Selection guide

Check IEC 62930 or project-approved equivalent, rated DC voltage and conductor area, sunlight and ozone exposure, temperature limits, minimum bend radius, copper construction, sheath and routing. Do not use generic LV AC cable as an assumed substitute.

Ask about this →

Grenglo coordinates project electrical material enquiries and refers dedicated cable product requirements to the specialist SGCables channel. These families are technical selection examples, not a stock list or a claim of manufacturing or OEM authorisation.

Engineering buyer guide

Selection criteria that matter

Request the cable schedule first: conductor size, number of cores/pairs, Uo/U or Vdc, insulation, screens and armour, fire criteria, drum lengths and destination. Keep specialised cable search intent primarily on SGCables; this Grenglo page acts as a project-sourcing overview.

FactorSpecification to sendTechnical note
Voltage / currentUo/U/Um for AC or rated Vdc for PV; conductor areaMatch circuit voltage and current-carrying capacity to design conditions.
Conductor constructionCu/Al, mm², class and number of coresClass affects flexibility and terminal compatibility.
Cable constructionXLPE/PVC/LSZH, screen, armour and sheathConstruction and protective components depend on installation.
Control versus instrumentCore count versus twisted pairs/triads, screening and capacitanceInterference susceptibility and signal integrity differ.
Fire evidenceIEC 60332, 60754, 61034 and 60331 tests where requiredLSZH does not automatically establish circuit integrity.
Operating environmentAmbient temperature, moisture, oils, UV and corrosionReview actual manufacturer's declared ratings.
Drums and cutsIndividual cut lengths, drum type, packing and overlengthTotal metres alone may yield unusable delivery lengths.
Project acceptanceClient cable schedule, datasheet revision, certificates and originRequire verifiable test or conformity documents for offered product.
Engineering FAQs

Frequently asked questions

How do I specify a 0.6/1 kV XLPE cable for Singapore?

Provide conductor material and size, cores, armour, sheath, IEC/project reference, required lengths, route conditions and destination. Rating and installation design remain the engineer's responsibility.

Is LSZH the same as fire-resistant cable?

No. Smoke/halogen behaviour, flame spread and maintained circuit integrity are distinct characteristics and require relevant test evidence.

Why use twisted pairs for instrumentation cables?

Signal pairs and controlled screening help address electromagnetic interference. Cable selection also depends on circuit capacitance, design and grounding.

Is a 4-core control cable interchangeable with a 2-pair instrument cable?

Not automatically. Pair formation, shielding, electrical parameters, conductor ID and approved project requirements may differ.

Can standard LV power cable be used as PV string cable?

Not by assumption. PV DC voltage, outdoor exposure, temperature and applicable PV cable standard must be satisfied.

Can SGCables handle specialist cable RFQs?

Yes. Grenglo directs dedicated cable enquiries to its SGCables channel while coordinating wider electrical project BOQs.

Need something not listed here?

These families are a starting point, not a full catalogue. Send the manufacturer part number, a nameplate photo or your schedule and we will check the supply route.